Maintaining the Projector 95
5. Loosen the lamp cover screws (you don’t need to take them out all
the way). Then remove the cover.
6. Loosen the three screws holding the lamp in place (you can’t
remove them).
7. Grasp the wire handle as shown and pull the lamp straight out.
8. Gently insert the new lamp.
9. Once the lamp is fully inserted, tighten its screws and replace the
cover. (The projector won’t come on if the lamp cover is loose.)
10. Reset the lamp timer as described in the next section.
aution
void touching the glass
ortion of the new lamp.
Oils transferred from your
ands can cause the lamp to
overheat and fail
rematurely.
2
1
note
When you get a replacement
lamp for your projector, new
air filters are included. This
is a good time to install them
(see page 92).