CONFIDENTIAL
RP-U420 Character commands ESC %
Ver. 1.0
p. 34
■ ■ ■
more
■ ■ ■
more
ESC %
S
ETTING
COMMAND
[Name]
Select/cancel user-defined character set
[Format]
ASCII ESC %
n
Hex 1B 25
n
Decimal 27 37
n
[Range]
0
n
255
[Default]
n
= 0
[Description]
Selects or cancels the user-defined character set.
When the Least Significant Bit (LSB) is 0, the user-defined character set is canceled and the internal character
set is enabled.
When the LSB is 1, the user-defined character set is selected.
[Notes] Only the LSB of
n
is valid.
When the user-defined character set has been released, the internal character set is specified
automatically.