Epson PowerLite 5000 Servisní příručka Strana 59

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 127
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 58
EPSON PowerLite 5000 Service Manual
2-29
fuse on this board is connected to the ground through a resistance (88 ).
Consequently, the fuse is blown and the LLIFE signal is switched from HIGH to LOW.
When LLIFE becomes LOW, IC600 switches LPCTL to HIGH and shuts down the lamp
power (65 VDC) from the power supply unit. When the power is shut off, and LPST
(LPFAL) becomes HIGH, IC600 detects power off in the lamp and starts the cooling
down sequence.
2.13 SENSORS/SWITCHES
The following devices listed in the table are installed in the projector for safe operation and
prevention of malfunctions.
Table 2-7 Sensors/switches
Name Location/Type Function/Use
Filter cover switch Micro switch on the lower
case
Turns power off when the filter
cover is open. (Power on is
disabled.)
Interlock switch Push-switch on the power
supply unit
Turns power off when the
lamp cover is open. (Power on
is disabled.)
Safety switch Thermal switch on the lamp
outer housing
Overheating protection for the
lamp area. Power is shut off if
the temperature exceeds a
specified limit.
Lamp thermistor Thermistor on the lamp outer
housing
Overheating protection for the
lamp area. Power is shut off if
the temperature exceeds a
specified limit.
LV thermistor Thermistor on the prism duct Overheating protection for the
light bulb. Power is shut off
when the temperature
exceeds a specified limit.
PBS thermistor Thermistor on the side of the
power supply unit
Overheating protection for the
power supply unit. Power is
shut off when the temperature
exceeds a specified limit.