Blastware Compliance Module
___________________________________________________
4–90 Blastware Operator Manual
connection. Serial Idle Time is the amount of time the monitor allows without any exchange with
the PC before terminating the connection.
(8) Command Buttons
To choose one of the following command buttons, click the mouse pointer on the button.
• Send
Press this to send your settings to the unit.
• Close
Leave the dialog box without changing the current settings.
b. Setup PC
You are able to access the Setup PC command from two locations;
1) Remote Access Menu > Auto Call Home > Setup PC, or
2) Remote Access Menu > Auto Call Home > Start, then Settings Menu > PC Setup.
Either command will store and access the settings you enter.
The Setup PC command opens the Auto Call Home PC Setup dialog box, where you setup your
PC for communication with remote monitors. You must tell Blastware which monitors to expect
modem communications from. When the monitor phones in, the software checks the monitors
serial number against the settings contained in the Auto Call Home PC Setup dialog box. If it
finds a match, it executes the instructions you have specified.
(1) Remote Unit Serial No.
Enter the serial numbers of the Blastmate III or Minimate Plus units that you wish to use with
Auto Call Home. Click on the text box and enter the serial number.
You can also create a single set of actions to be performed when any remote monitor calls in
to your PC. In the first Remote Unit Serial No. field, enter the * character as the serial
number. Then click on the Edit button to set the actions (see below). Blastware applies these
actions to any monitor that calls in.
Note: Auto Call Home is supported by Blastmate III or Minimate Plus units with a
serial number of 6000 or greater, or any Series IV unit.
(2) Description of Actions
This area displays the description entered for the unit. The description cannot be edited here.
Click on the Edit button (see below) to change your description.
(3) Edit
The Edit button invokes the Auto Call Home Actions dialog box. In this dialog box you tell
Blastware what actions to perform when the monitor calls in.