Epson CMD-2260 (CD-ROM) Technické informace Strana 136

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 224
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 135
Blastware Compliance Module
___________________________________________________
4–112 Blastware Operator Manual
ii Blastware is reading the response of the 10 Bytes that were sent:
iii The message window indicates that 10 Bytes were successfully sent and read – if you
receive an error, check the modem connections, setup and status, and ensure that each piece
of equipment is turned on:
iv If the Loop Test is not successful, the window will prompt you with a series of
messages, similar to the following:
“Writing 100 bytes”
“Loop #10: Trying to read 100 Bytes”
“100 of 100 chars were read correctly”
“100 of 200 Error at char 101”
The last line indicates an Error, stating that character 101 does not match what was sent out.
If a Loop Test is not able to be performed at all, the message “Connection failed” is displayed,
indicating that the software could not open the communication socket. Review and check the
status and setup of the modem.
(9) Communications from a Unit
Ensure that the modem is setup up and working properly. To test the communications from a unit,
first turn the unit off, and then manually wake up the unit, wait 10 seconds and click on OK.
Zobrazit stránku 135