Blastware Compliance Module
___________________________________________________
5–10 Blastware Operator Manual
a. Timer Mode
The timer can be set for a one time operation or repeated operations at the same time each day.
To select a timer mode, click on the Timer Mode drop–down menu and select the required option.
Choose Off to disable the timer. Choose Monitor Once Only if you want the monitor to turn on
and record a single session, then turn off. Choose Monitor Every Day if you want the monitor to
turn on and record at the same time every day beginning immediately.
(1) Start Date
Enter the calendar date for the monitor to turn on.
(2) Start Time
Enter the time of day for the monitor to turn on and start monitoring. Change the time format
between the twenty-four-hour clock and the twelve-hour clock in the Report Options dialog box
located within the Options Menu.
(3) Stop Date
Enter the calendar date to turn the monitor off.
(4) Stop Time
Enter the time of day to turn the monitor off and stop monitoring.
b. Daily Self Check (Blastmate II only)
Use the self check mode for remote monitoring where you require a record indicating the monitor
was operating properly over a period of time. The self check mode program operates when the
monitor is in the monitor mode. The monitor temporarily exits the monitor mode, at the same time
each day specified by you, performs the check, and returns to monitor mode. The results appear in
a monitor log entry.
To set the self check mode, move the mouse pointer to the Self Check Mode drop-down menu
and choose On to turn the self check mode on. Choose Off if you do not require self check to
operate.
(1) Time
Enter a time for the Self Check Mode to run. Click on the Time boxes and enter a time.
To choose one of the following command buttons, click the mouse pointer on the button.
c. Command Buttons
To choose one of the following command buttons, click the mouse pointer on the button.
i OK
Accept the changes and do not exit the dialog box.
ii Cancel
Cancel the changes and return to the previous window.
iii Apply
Apply the changes and exit the dialog box.
5.4.4 Status
The Status command checks the monitor and displays the following information.
To display the Status dialog box, select Unit menu, then click on Status. Press the Refresh button
to update the information. Press the Cancel button to return to the Blastware Main Menu, and the
Print button to print out a copy of the Status settings.